multiphysics simulations of microfluidic channels Search Results


90
COMSOL Inc multiphysics simulations of microfluidic channels
Illustration of <t>Microfluidic</t> Flip-Chip ( A ) Image shows the fabricated MFC using a soft lithography process along with the illustration. ( B ) A graphic illustration of the MFC shows the three-layered structure with PDMS channels as the top layer, through-hole membrane as the middle layer, and titanium electrodes as the third bottom layer. ( C ) The parameters affecting chip performance—the PDMS membrane thickness (t m ), the diameter of fusion well (d w ), the distance between adjacent wells (d aw ), the distance between electrodes (d), and the distance between adjacent electrodes (d ae ) are as shown. Scale bar: 200 µm.
Multiphysics Simulations Of Microfluidic Channels, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/multiphysics simulations of microfluidic channels/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
multiphysics simulations of microfluidic channels - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

90
COMSOL Inc multiphysics simulation of the flow rate through the microfluidic channel layer
Diagram of the <t>microfluidics-based</t> laser guided cell-micropatterning system.
Multiphysics Simulation Of The Flow Rate Through The Microfluidic Channel Layer, supplied by COMSOL Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/multiphysics simulation of the flow rate through the microfluidic channel layer/product/COMSOL Inc
Average 90 stars, based on 1 article reviews
multiphysics simulation of the flow rate through the microfluidic channel layer - by Bioz Stars, 2026-03
90/100 stars
  Buy from Supplier

Image Search Results


Illustration of Microfluidic Flip-Chip ( A ) Image shows the fabricated MFC using a soft lithography process along with the illustration. ( B ) A graphic illustration of the MFC shows the three-layered structure with PDMS channels as the top layer, through-hole membrane as the middle layer, and titanium electrodes as the third bottom layer. ( C ) The parameters affecting chip performance—the PDMS membrane thickness (t m ), the diameter of fusion well (d w ), the distance between adjacent wells (d aw ), the distance between electrodes (d), and the distance between adjacent electrodes (d ae ) are as shown. Scale bar: 200 µm.

Journal: Cells

Article Title: A Microfluidic Flip-Chip Combining Hydrodynamic Trapping and Gravitational Sedimentation for Cell Pairing and Fusion

doi: 10.3390/cells10112855

Figure Lengend Snippet: Illustration of Microfluidic Flip-Chip ( A ) Image shows the fabricated MFC using a soft lithography process along with the illustration. ( B ) A graphic illustration of the MFC shows the three-layered structure with PDMS channels as the top layer, through-hole membrane as the middle layer, and titanium electrodes as the third bottom layer. ( C ) The parameters affecting chip performance—the PDMS membrane thickness (t m ), the diameter of fusion well (d w ), the distance between adjacent wells (d aw ), the distance between electrodes (d), and the distance between adjacent electrodes (d ae ) are as shown. Scale bar: 200 µm.

Article Snippet: COMSOL Multiphysics simulations of microfluidic channels, Figure S3.

Techniques: Membrane

Diagram of the microfluidics-based laser guided cell-micropatterning system.

Journal: Biofabrication

Article Title: Microfluidics-Based Laser Guided Cell-Micropatterning System

doi: 10.1088/1758-5082/6/3/035025

Figure Lengend Snippet: Diagram of the microfluidics-based laser guided cell-micropatterning system.

Article Snippet: A COMSOL multiphysics simulation of the flow rate through the microfluidic channel layer ( ) was conducted to determine the exit velocity of cell-suspensions from the microchannels. shows the simulation results based on the rectangular dimensions described in Section 2.2.1.

Techniques:

An exploded assembly and overall diagram of the microfluidics-based cell-delivery biochip and cell-culture substrate.

Journal: Biofabrication

Article Title: Microfluidics-Based Laser Guided Cell-Micropatterning System

doi: 10.1088/1758-5082/6/3/035025

Figure Lengend Snippet: An exploded assembly and overall diagram of the microfluidics-based cell-delivery biochip and cell-culture substrate.

Article Snippet: A COMSOL multiphysics simulation of the flow rate through the microfluidic channel layer ( ) was conducted to determine the exit velocity of cell-suspensions from the microchannels. shows the simulation results based on the rectangular dimensions described in Section 2.2.1.

Techniques: Cell Culture

(A) 2D schematic of the microfluidic biochip flow-channel layer (depth is 50 μm). (B) Phase contrast image (20×) of a microchannel cross-section. Scale bar 50 μm.

Journal: Biofabrication

Article Title: Microfluidics-Based Laser Guided Cell-Micropatterning System

doi: 10.1088/1758-5082/6/3/035025

Figure Lengend Snippet: (A) 2D schematic of the microfluidic biochip flow-channel layer (depth is 50 μm). (B) Phase contrast image (20×) of a microchannel cross-section. Scale bar 50 μm.

Article Snippet: A COMSOL multiphysics simulation of the flow rate through the microfluidic channel layer ( ) was conducted to determine the exit velocity of cell-suspensions from the microchannels. shows the simulation results based on the rectangular dimensions described in Section 2.2.1.

Techniques:

A single CFN at 16 hours: It was selected from the microfluidic cell-delivery channel and laser-micropatterned onto a PDMS-based cell-culture substrate.

Journal: Biofabrication

Article Title: Microfluidics-Based Laser Guided Cell-Micropatterning System

doi: 10.1088/1758-5082/6/3/035025

Figure Lengend Snippet: A single CFN at 16 hours: It was selected from the microfluidic cell-delivery channel and laser-micropatterned onto a PDMS-based cell-culture substrate.

Article Snippet: A COMSOL multiphysics simulation of the flow rate through the microfluidic channel layer ( ) was conducted to determine the exit velocity of cell-suspensions from the microchannels. shows the simulation results based on the rectangular dimensions described in Section 2.2.1.

Techniques: Cell Culture

COMSOL simulation for the flow rate of cell-suspensions through the microfluidic biochip.

Journal: Biofabrication

Article Title: Microfluidics-Based Laser Guided Cell-Micropatterning System

doi: 10.1088/1758-5082/6/3/035025

Figure Lengend Snippet: COMSOL simulation for the flow rate of cell-suspensions through the microfluidic biochip.

Article Snippet: A COMSOL multiphysics simulation of the flow rate through the microfluidic channel layer ( ) was conducted to determine the exit velocity of cell-suspensions from the microchannels. shows the simulation results based on the rectangular dimensions described in Section 2.2.1.

Techniques:

Fluorescence and phase contrast combined image (40x) of a laser-micropatterned CFN array. The two DiI live-stained cells (red) were from one microfluidics-cell-delivery channel, the remainders were from the other channel. Scale bar 25 μm.

Journal: Biofabrication

Article Title: Microfluidics-Based Laser Guided Cell-Micropatterning System

doi: 10.1088/1758-5082/6/3/035025

Figure Lengend Snippet: Fluorescence and phase contrast combined image (40x) of a laser-micropatterned CFN array. The two DiI live-stained cells (red) were from one microfluidics-cell-delivery channel, the remainders were from the other channel. Scale bar 25 μm.

Article Snippet: A COMSOL multiphysics simulation of the flow rate through the microfluidic channel layer ( ) was conducted to determine the exit velocity of cell-suspensions from the microchannels. shows the simulation results based on the rectangular dimensions described in Section 2.2.1.

Techniques: Fluorescence, Staining